Thank you for this very useful script. I marvel at the level of knowledge that it takes to create such a script. Until now I have not been able to get any terminal program that I have evaluated to behave exactly as needed in my application. But, with the building blocks that you have provided, I have realized a proper configuration at last. Online Cialis. Viagra Online without prescription 50/100 mg. Online Cialis. Fast order delivery. Bonus 10 free pills, discounts and FREE SHIPPING. The result will be incorporated in a computer-based system that provides magnification services to individuals with low vision. The script controls the the parameters of the display through the display's serial port. Again, my appreciation for this most helpful contribution. Hi Ron1, Thanks for the compliment. Siemens pol687 ip address default password. Click the Wireless Controller button to open the Wireless Controller Configuration screen. Once you get in you can use these steps to reset it: a. If you can find the ipddress range of the non-working vlan that the AP is in you can change your computer ip address to one in that range and then access the router with it's ipaddress. I'm glad that you have found it useful and are putting it to such a noble cause. Well, necesity is the mother of invention. It's funny that I was only about 26.4ms away from not developing this WinDLL version. For my application, I am using AHK to communicate with my companies ICs. I first started using Port.dll and after several days of development I was finally at the point of where I should have been able to communicate with the ICs, however, I kept getting NACK (Not Acknowlege). I probed the Serial Port Tx line on the oscilloscope and noticed that there was only one byte of data being transmitted every 15.8ms - I was sending 8 bytes (8*15.8ms=126.4ms). It turned out that if our ICs didn't get all 8 bytes of data in 100ms then they timed-out and sent NACK. It took me about another 2 weeks to develop the WinDLL version. But to be honest, I couldn't have done it without the help of Lexikos. If I do say so myself, I've done some pretty amazing things with AHK. In one case, I wrote a test automation script (in one week), which would have taken a team of software developers several months with conventional methods, saving my companies ass in the process. And they don't even know it. I particularly enjoy automating Windows based test equipment. I automated a (Big Name) pattern generator (took me about a month) they have a team of people working more than 6 months now, trying to accomplish the same thing and they come to me for help. This is the first time that I have made any contribution to an Open Source community and I'm honored for the opportunity. Assuming you changed StringLeft value to 5 making%COM_Port% == COM17, it should be right, but then again it may be bumping the predicted string length in some other portion of the script. I agree, this is poor coding. Before going any further with AHK, I would suggest trying to connect using the command line tool called SerialTerm (you can find a link on these forums) or download the newest Putty and connect through it. Once you've established a connection, having all your other variables in order (baud, parity, etc), then try again with AHK. Casio cz sysex patches for jackets for sale. Of course, make sure these are closed first (only one may connect at a time). Hi Raccoon, Yes, I agree that it isn't the best coding in the world. I'm actually not happy with the whole flow of the script, but I wanted an easy way to demonstrate the script and I didn't know how to do it any other way. Your way is much better. Thanks for the suggestions. I'll put them in soon. Krisky, I'll also look into the single digit console problem, but when I test this script I actually test it in loop back mode -- 2 com ports on the same pc running 2 different copies of the same script. So I don't have any problem using different com port numbers. I'll try to get the changes in by the end of the week. ![]() ![]() Usb serial emulation driver uni directional carbon. I am trying to connect to the network console ports using the serial functionality in Putty. I have configured Putty to use the COM1 port when using the serial connection. But each time I try using this serial connection, I receive an error saying 'unable to open connection to COM1.Unable to open serial port.' It worked just fine when using Putty and the serial port over the COM1 in Windows 7, but I no longer have that functionality in Windows 8. Is there a setting that needs to be changed or is Windows 8 not capable of using this feature now? How do I find out which program is using the port and how do I disconnect it? I don't know but I just found something that might help using WMIC. Portconnector Data presented corresponds to this Unfortunately it appears that the Status field is not being used correctly. Also, I don't know how accurate this will be because it is showing me I have a PS2Mouse on my Surface!; } Hmm. More usefully I think in the sidebar I noticed Win32_SerialPort which led me to Path CIM_SerialController (e.g.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |